Maxiflex 16AI I/O Module
Maxiflex 16AI module. 16 channel analog input. Various volt and current ranges. 8 inputs/common -ve.
Maxiflex 16AI module. 16 channel analog input. Various volt and current ranges. 8 inputs/common -ve.
Maxiflex 16 DI 48V module. 16 channel digital inputs (30-60Vdc). Nominal 48Vdc. Positive or negative common. 8 inputs/common.
Maxiflex 16 DI 24V module. 16 channel digital inputs (9-30Vdc). Nominal 24Vdc. Positive or negative common. 8 inputs/common.
Maxiflex 16DO module. 16 channel Digital Output. Open-collector transistors. Terminals and Ribbon outputs. 5-80Vdc, 200mA per channel. 8 outputs/common.
Maxiflex 19 Inch Mounting Adapter for Maxiflex Bases. Caters for 3, 5, 7 I/O Master Bases 5 and 8I/O expanders.
Maxiflex 2I/O Master Base for PSU, CPU and any 2 I/O Modules. Not expandable to expander base.
The Maxiflex 2PFC Module is used to monitor dual inputs flow meters and to detect and correct errors in the input pulse streams. The module is designed to achieve the functionality of Level A security requirements of specification ISO 6551
Maxiflex 3I/O Master Base for PSU, CPU and any 3 I/O Modules. Expandable to M1023A expander base using cable M1811A. Can expand to other expander bases too.
Maxiflex 3I/O Master Base for PSU, CPU and any 3 Mx I/O Modules. Expandable to M1031/2 expander bases using cable M1811A.
Maxiflex 32 DI 24V module. 32 channel digital inputs (18-30Vdc). Nominal 24Vdc. Positive or negative common. 16 inputs/common. Requires 2 off Fastrak Field Terminal Board C632X and Ribbon Cables
Maxiflex 32DO module. 32 channel Digital Output. Open-collector transistors. Ribbon Header outputs. 18-30Vdc, 100mA per channel. 16 outputs/common. Requires 2 Off Fastrak Field Terminal Board C632X and Ribbon Cables
Maxiflex 32 Channel Sequence Of Events Recorder Module. Accepts Potential Free contacts and 30-60Vdc. Date and Time Stamps sequence of events to 1millisecond resolution. Requires Field termination board C6332B and Interface cable C1467B
Maxiflex 32 Channel Sequence Of Events Recorder Module. Accepts Potential Free contacts and 9 to 30Vdc. Date and Time Stamps sequence of events to 1millisecond resolution. Requires Field termination board C6332B and Interface cable C1467B
Maxiflex 4 Channel High Speed Counter Module. : Up to 200kHz.
The Maxiflex 4PI Module is used to monitor dual inputs from up to four flow meters and to detect and correct errors in the input pulse streams. The module is designed to achieve the functionality of Level A security requirements of specification ISO 6551
Maxiflex 4 channel ISO 32 bit precision 4 Wire RTD input module. Supports Pt100 STD. Range -115 to 327C.
Maxiflex 5 I/O Expander Base for any I/O modules. No extra PSU module required.
Maxiflex 5 I/O Expander Base for any I/O modules. No extra PSU module required.
Maxiflex 5I/O Master Base for PSU, CPU and any 5 I/O Modules. Expandable to M1032 or M1032A expander base using cable M1811A. Can expand to other expander bases too.
Maxiflex 5I/O Master Base for PSU, CPU and any 5 I/O Modules. Expandable to M1031/2 expander bases using cable M1811A.
Maxiflex 64 DI 24V module. 64 channel digital inputs (18-30Vdc). Nominal 24Vdc. Positive common. 16 inputs/common. Requires 4 off Fastrak Field Terminal Board C632X and Ribbon Cables
Maxiflex 6DI module. 6 Digital Inputs. Used for Electrical Breaker control/monitoring.
Maxiflex 6DI2DO module. 6 Digital Inputs and 2 Relay Outputs. Used for Electrical Breaker control/monitoring.
Maxiflex 6DI8DO module. 6 Digital Inputs and 8 Relay Outputs. Used for Electrical Breaker control/monitoring.
Maxiflex 6 channel ISO RTD input module. Supports Pt100 and Ni120 STD. Input range and RTD type may be different for each channel. Each channel can have 4 Setpoints High, High High, Low, Low Low and deadband set in config download.
Maxiflex 6 channel ISO RTD input module. Supports Pt100 and Ni120 STD. Input range and RTD type may be different for each channel. Each channel can have 4 Setpoints High, High High, Low, Low Low and deadband set in config download.
Maxiflex 7I/O Master Base for PSU, CPU and any 7 Mx I/O Modules. Expandable to M1031/2 expander bases using cable M1811A.
Maxiflex 8 I/O Expander Base for any I/O modules. Separate PSU module required for this base.
The M1434A 8AI ISO 8 channel analogue input module provides 8 inputs that can be individually configured for millivolts, Volts, Current or Thermocouple inputs. You can scale the input value in the module into Engineering Units of the your choice
The M1434 8AI ISO 8 channel analogue input module provides 8 inputs that can be individually configured for millivolts, Volts, Current or Thermocouple inputs. You can scale the input value in the module into Engineering Units of the your choice
The M1434 8AI ISO 8 channel analogue input module provides 8 inputs that can be individually configured for millivolts, Volts, Current or Thermocouple inputs. You can scale the input value in the module into Engineering Units of the your choice
The M1434 8AI ISO 8 channel analogue input module provides 8 fully isolated voltage (1-5V) inputs
Maxiflex 8AO module. 8 channels analog out (4-20mA). Individual common -ve terminals, commoned internally.
Maxiflex 8DI-C module. 8 Potential-free contacts or contacts with up to 200Vdc across them. Full isolation between channels. 1 input/common.
Maxiflex 8DI4AI module. 8 Digital Inputs and 4 bi-polar Analog Inputs. Used for Electrical Breaker status monitoring and for V, I or other transducers (-5 to +5mA).
Maxiflex 8DI8RO Module. 8x 9-30Vdc Digital Inputs 8 Relay Output (shared common).
8 Independant Channel Hart NIM for Inteface to HART enabled devices to send and retrieve data
Maxiflex 8 Channel High Speed Counter Module. Channels 1-7: up to 1kHz. Channel 8: up to 10kHz.
Maxiflex 8RO module. 8 N/O relay contacts. 5A 250Vac. Full isolation between channels. 1 output/common.
Maxiflex 8 channel ISO TC/mV input module. Supports Type E,J,K,T,N,B,R,S Thermocouples.Input range and TC type may be different for each channel. Each channel can have 4 Setpoints High, High High, Low, Low Low and deadband set in config download.
Showing 1–40 of 128 results